Pico Technology TC-08 8 Channel Thermocouple Data Logger, Temperature Data Recorder, Temp Range 270 to +1820 °C, Free Cloud Software for Mac, PC and Linux

£498.735
FREE Shipping

Pico Technology TC-08 8 Channel Thermocouple Data Logger, Temperature Data Recorder, Temp Range 270 to +1820 °C, Free Cloud Software for Mac, PC and Linux

Pico Technology TC-08 8 Channel Thermocouple Data Logger, Temperature Data Recorder, Temp Range 270 to +1820 °C, Free Cloud Software for Mac, PC and Linux

RRP: £997.47
Price: £498.735
£498.735 FREE Shipping

In stock

We accept the following payment methods

Description

and better still, utilising the Power over Ethernet (PoE) capability on the Raspberry Pi 3B+ paired with the PoE PiHAT not only eliminates the need for an external power supply and powered USB hub, it also internet-enables your logger at the same time When the Humidity Probe was in stalled: Win Wiz found new hardware. They selected Yes & it auto found a Driver on the CD.

If users wish to install the last release of PicoScope 6 Beta for Mac (6.14.62), you can do so here. Release notes Picoscope 7.1.17 Early Access Not many USB scopes works on Win & Mac & Linux too, so that proves me that guys from Pico really cares about us, customers. This made my decision much easier when I was looking to buy an USB scope. We were a bit hesitant at first … but it worked flawlessly, and everybody is now out shopping for PicoScopes! Perfect Partner for Development of Encoder controlled Stepper Motor Actuators. Since the included software is really stable, this type of device is a great tool for great tasks!The TC-08 connects to the USB port of a Windows based PC and enables the host PC to automatically detect the TC-08 avoiding the need for any complex setup procedures. The USB connection also allows the TC-08 to be powered directly by the USB bus eliminating the need for an external power supply and making the TC-08 ideal for measuring temperatures both in the lab and in the field.

To explain why, you need to know about measurement goals, terminology, limits of measurement system capabilities, and more, so the complete answer (if you're interested) is as follows: Alternatively, the resolution of the TC-08 is considerably better than the accuracy of a high precision, high accuracy thermistor. So, if you are in fact just looking for high precision changes then you already have that capability in your TC-08, and probably don't need to concern yourself with accuracy, calibration, and multiple capture sessions.

8 channel thermocouple data logger

It is a great scope. I had a weird problem - it did not work on one of my PC’s. Customer service gave me first class service. If I could give 6 stars for customer service - I would do so. The TC-08 can be used with thermocouple types J, K, T, E, R, S, B and N and outputs can be viewed in degrees F, C or mV. The unit is accurate to 0.2 percent ± 0.5 degrees C and has a resolution of better than 0.1 degrees C for most thermocouple types. The Early Access version can also be installed alongside the stable version on Windows and Mac, and will receive independant update notifications for all of the new features added with each release. Rather than webcam our benchtop scope screen, it was suggested we use a PicoScope to share waveforms via screen share.

You can now connect the logger to the Pi and remove the keyboard, mouse and video to make an inexpensive stand-alone logger storing its captured data locally on a Pi SD card and better still, utilising the Power over Ethernet (PoE) capability on the Raspberry Pi 4Bpaired with the PoE PiHAT not only eliminates the need for an external power supply and powered USB hub, it also internet-enables your logger at the same time In considering your measurement goals it's worth bearing in mind that, high temperature accuracy (how close the converted temperature value being logged is to the true temperature being measured) is more difficult to achieve when compared to other types of measurement (the ITS-90 standard, upon which all current temperature measurements are based, is only accurate to 5 decimal places, and unlike some other standards, e.g. derived at atomic level, using unique methods, ITS-90 was derived using more precise variants, of generally used apparatus and methods, e.g. a gold standard PT100 sensor, the triple point of water, and other known preset points). However, high temperature precision (the smallest measurable difference between 2 temperature values) is easier to achieve, with your average Data Acquisition Device typically having a resolution (which is essentially the digital equivalent of precision) of at least 10 times it's accuracy. The resolution of the TC-08 is approximately 100 times it's accuracy. As you are interested in how the NTC sensor changes relative to a fixed resistance value, I would say that what you need is a measurement system capable of high precision, rather than high accuracy. However, for completeness, we will discuss both precision and accuracy.Pico Log cannot select the TC-08 and refresh does not help. It sees the Humidity Probe straight away and just loads it without request. Nothing in the help talks about Hardware drivers and nothing makes a connection even though it has the DLL and knows what and where it is. It is also possible to set an alarm when a device becomes disconnected:an alarm is turned on, the event recorded and the graph annotated to show that the lost data was due to device disconnection.

We have been using Picoscope 6404D for quite some time, and are amazed by its accuracy and powerful emulations while working with numerous signal evaluations. The TC-08 thermocouple data acquisition module is designed to measure a wide range of temperatures using any thermocouple that terminates in a miniature size thermocouple connector. Additionally the TC-08 can also measure other sensors using a ±70 mV range. Featuring built-in cold junction compensation (CJC), the TC-08 has an effective measuring range of -270 to 1820°C (the actual temperature range depends on the thermocouple type being used). Furthermore, connecting your Pi by WiFi or Ethernet, you can internet-enable your Pico logger which you can then access remotely using an open-source VNC server and viewer freely available Pico Technology data loggers work great when USB connected to PCs running Windows, macOS and Linux, and now with support for Raspbian OS on armhfprocessors, we support Raspberry Pi computers.Great functionality in a compact size. I really like moving the mouse pointer to a position and having the Time and Voltage display the values at that point. Calibration equipment is a breeze with that feature. Pico Technology data loggers work great when USB connected to PCs running Windows, macOS and Linux, and now with support for Raspbian OS on armhfprocessors, we now support Raspberry Pi computers. You can reduce the systematic uncertainties due to measurement session variation by repeatedly taking the same measurements. By doing all this, the difference in accuracy between the TC-08 and a high precision, high accuracy thermistor should be easy enough to overcome. PicoLog 6 alarms can also trigger a digital output on devices with supporting hardware, such as the PicoLog 1000 Series, ADC-24 and DrDAQ. You can even trigger a digital output from one of these devices based on an alarm condition from another connected logger without digital outputs, such as a TC-08.



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop