Fluke T6-1000 PRO Electrical Tester

£151.775
FREE Shipping

Fluke T6-1000 PRO Electrical Tester

Fluke T6-1000 PRO Electrical Tester

RRP: £303.55
Price: £151.775
£151.775 FREE Shipping

In stock

We accept the following payment methods

Description

Standardní dvouletá záruka smožností prodloužení na 4roky při zaregistrování produktu do 45 dnů ode dne zakoupení * FieldSense ™ technology is different than other open fork testers work by interpreting a magnetic field to show AC current. FieldSense™ detects an electrical field that interacts with a T6 reference signal, showing a voltage value on the tester’s display. The Fluke T6-1000 PRO Electrical Tester is an ergonomic, easy-to-use, and efficient voltage and current open-fork meter with FieldSense technology. Fluke T6-1000 PRO Electrical Tester Key Features Accuracy [1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding.

An annual visual examination by a suitably trained person is recommended to determine the suitability of the Insulated Hand Tool for further service. If an electrical retest is required by national regulation or in the case of doubt after visual examination, the applicable dielectric test of IEC 60900 for insulated hand tools should be performed. Industrial electricians working with gloves and other PPE, who work in dark or noisy areas, and need fast, safe voltage and current measurements, up to 1000 V and 200 A at the same time. Simultaneous voltage and current display – shows all power supply measurements at a glance for efficient trouble shooting Voltage measurement requires capacitive path to ground, provided through user in most applications. Ground connection via test lead may be required in some situations. Accuracy [1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC measurements are ac-coupled, RMS responding.Before use, each Insulated Hand Tool should be visually inspected by the user. If there is any doubt concerning the safety of the insulated hand tool, it should be subjected to examination by a competent person and if necessary retested to determine suitability or disposed of to prevent further use. There‘s no need to find a metallic test point - FLUKE‘s FieldSense technology shows you voltage and current at the same time. Insert the wire to the middle of the open fork and see accurate voltage and current measurements. The T6-1000 PRO shows you both without touching a live wire. Do not apply excessive force or stress to the tool insulation that may cause damage. Examples include using the insulated surfaces as a fulcrum to pry or wedge or gripping insulated tool handles with other tools such as pliers or wrenches to increase torque or leverage.

Insulated Hand Tools should be used only in environments having temperatures between –20 °C and +70 °C and, for tools marked “C”, between –40 °C and +70 °C. Learn how to use your new T6 with revolutionary “Field Sense” technology and get the best of your continuity tester. Here are some hints to keep in mind when using it. A voltage tester and a current tester at the same time.Současné zobrazení napětí aproudu – při řešení poruch motorů, čerpadel adalšího vybavení; měřte napětí iproud zároveň aušetřete čas

The following is guidance concerning the maintenance, inspection, retest and use of Fluke Insulated Hand Tools. Accuracy [2]: Add 3 % without an external ground connection. External ground connection required for user wearing insulated gloves, standing on an insulated ladder, or otherwise insulated from earth ground.

Přesnost [1]: ±([% naměřené hodnoty] + [rozdíl na nejnižším zobrazeném řádu]). Přesnost je stanovena pro 1 rok po kalibraci, při 18 až 28 °C (64 až 82 °F) srelativní vlhkostí do 90 %. Převod střídavého proudu je kapacitní vazbou na efektivní hodnotu. FLUKE T6-1000 PRO with FieldSense makes your job faster and easier with increased safely and faster answers!

Accuracy[1]: ± ( [ % of reading] + [number of least significant digits] ). Accuracy is specified for 1 year after calibration, at 18 °C to 28 °C (64 °F to 82 °F) with relative humidity to 90 %. AC conversions are ac-coupled, RMS responding. Simultaneous voltage and current display–save time by seeing voltage and current measurements at the same time when trouble shooting motors, pumps or other equipment Make life easier with visual continuity. The Screen will light up green so you can see continuity in loud or dark areas. With a jaw opening of 17.8mm/0.7”, the Fluke T6-1000 PRO Electrical Tester can be used on wires up to AWG 4/0. It is easy to operate, even when wearing gloves, and compatible with an OPTIONAL Fluke TPAK Magnetic Meter Hanger, adding to its convenience.Temperature coefficient: 0.1 x (specified accuracy) / °C for <18°C or >28 °C (< 64.4 °F or > 82.4 °F)



  • Fruugo ID: 258392218-563234582
  • EAN: 764486781913
  • Sold by: Fruugo

Delivery & Returns

Fruugo

Address: UK
All products: Visit Fruugo Shop