of compacted sand is laid on the bottom of the trench, the fuel supply pipe positioned, and a further 40mm of compacted sand is laid above the pipe In 2021, oil (kerosene) continues to be the most widely used fuel in off-grid homes. However, to reflect that a renewable liquid fuel, such as HVO may soon be available (see our future heating section) we have used the term liquid fuel in this guide to include both oil and low carbon liquid fuels. Directly buried fuel supply pipes should be protected against the risk of accidental damage caused by digging. The recommended installation method is as follows: Label Source supply a comprehensive selection of pipe marking and identification tapes, all of which are manufactured to BS1710 and BS4800standards with the recommended colour schemes and constructions.

Detectable Oil Pipeline Below Underground warning Tape Detectable Oil Pipeline Below Underground warning Tape

A Selection of hazard warning underground tapes, each available with a different caution message and colour . Home guide to domestic liquid fuel storage up to 3500 litres Home guide to domestic fuel supply pipes OILS: Oils, including fuels and hydraulic or transformer fluids, need to be labeled with a brown outer ring.Domestic fuel supply pipes are usually made of plastic-coated soft copper tubing that can be easily manipulated.. Plastic pipe systems are also available but must only be used below ground and outside of buildings. Fittings and jointing materials must be suitable for the type of pipe and fuel being used. Liquid fuel supply systems

UK Tapes Ltd: UKT05OIL from the safety tape specialists

Material – Linear low density polyethylene Lead free pigments with virgin grade film Soil tolerance from pH 2.5 to pH 11.0 inclusive Pipe marking is a vital part of reassuring the health and well being of workers around pipes carrying gases, liquids or other elements that could potentially cause harm. The color of the pipe marking is specific to the element the pipe is carrying, which informs workers of the danger. Underground Warning Tape for marking buried services including underground cables and pipes - premium grade underground warning tape with ENATS 12-23 approval for cable and pipe marking.Fuel supply pipes are a vital part of any liquid fuel-fired heating system and it is important that they are installed and maintained correctly to ensure system reliability and safety. Correct installation also helps to avoid the risk of leaks, which can cause pollution and are costly to clean up. This guide applies to pipes that carry fuel to liquid fuel-fired appliances of up to 70kW output which are located at properties used primarily for domestic purposes. Fuel supply pipes What are the different pipe marking tapes available?Each pipe must be clearly identified using the correct pipe identification banding. Each tape is different depending on what is within the pipe, the most common are: The British Pipe Marking Standard requires that, at a minimum, pipe marking signs must be located on both sides of valves, service appliances, bulkheads, wall and floor penetrations, as well as any other place pipe contents identification is needed. These regulations are important to follow otherwise the marking will be invalid. Material – Linear low density polyethylene Lead free pigments with virgin grade film Soil tolerance from pH 2.5 to pH 11.0 inclusive 100 micron grade is manufactured in accordance with ENATS 12-23 Issue 3 2013 specification.

Tape | Pipe Identification Tape | Label Source Pipe Marking Tape | Pipe Identification Tape | Label Source

The purpose of the labelled pipe is indicated by pipe marking tape. It is required by law to label any pipes carrying hazardous materials with the substance name and the appropriate colour code. All pipeline identification tapes are made of 90 micron self-adhesive vinyl with a rubber-based adhesive and a clear polypropylene surface laminate. Our pipe tape has an operating temperature range of -10°Cto +50°C.

Liquid fuel supply systems

For best performance, fuel supply pipework should take the most direct route between the fuel tank and burner, while avoiding high points in the pipework, the creation of trip hazards, or anything likely to damage the pipe and joints. Pipes should be supported by purpose made clips and attached to permanent structures, such as a wall. A garden shed or wooden boundary fence is not classed as a permanent structure because it will deteriorate with age and any movement may damage the pipe and fittings. Buried fuel supply pipes entriforce Stokbord underground cable protection covers are heavy duty cable protection covers designed to withstand damage and protect HV cables from plant and hand tools - suitable for underground high voltage cable protection (22kV, 33kV, 66kV, 132kV and up to 400kV). This has led OFTEC to join forces with colleagues across the heating industry to research a low carbon liquid fuel alternative to heating oil. The fuel, called HVO, can be used as a direct replacement and offers a near 90% reduction in emissions. A fire valve is an essential safety feature of a fuel supply installation, which will stop the supply of fuel in the event of a fire or an overheat situation occurring at the appliance. The valve should be located outside the building, before the point of entry, and be activated by a remote sensor. Existing fuel supply pipes that are not accessible outside of the building, and do not have a fire valve, can have one added at the first point where the pipe appears internally. This is not permitted on a new pipe installation, but it can improve the safety of an existing installation. Fire valves are also required for externally located appliances. Your OFTEC registered technician will be able to offer advice on the correct selection and positioning of fire valves. Annual inspection

Oil Pipeline Detectable Warning Tape - 75mm x 50M - Directa UK

REFRIGERANTS: Refrigerants have several subcategories, including things like ammonia, and should be indicated by ochre rings (a yellow/maize color). How would I know if I need to use pipe marking tapes?Pipe marking signs are an essential part of dealing with potential safety issues, pipes that are exposed specifically above ground are a risk that must be highlighted using marking tape. The meaning behind this is due to the safety of those working around the pipes to enable the pipes to be visible and therefore less dangerous. When it comes to industrial piping, workers need a way to accurately and consistently identify the hazards they may face. Furthermore, BS 1710 states that pipe labeling is required if the pipes are actively carrying fluids or gases. An example of this could be elbows and connecting pieces (T-junctions), or junctions in which more than one pipe merges together (water used for multiple distinct purposes at one point may merge together in a large outflow pipe). Where a fuel supply pipe passes through the wall of a building it should be run within a sleeve, such as a larger plastic pipe. Fuel supply pipes should not be run underground directly into the interior of a building, instead the pipe should rise externally to allow a remote acting fire valve to be fitted before it enters the building. Fire valves

Fuel supply pipes

The tape serves the dual purpose of (1) allowing location from above ground and (2) providing a visual warning to prevent third party damage Fuel supply pipes should be buried at least 300mm clear of other underground services such as water and electricity. Joints should be avoided in buried pipework, if possible. If joints need to be made, they should be within an inspection chamber. Entry into buildings Whether you are already registered with OFTEC or simply want to find out a little more about what's involved with registering for OFTEC's Competent Persons, Microgeneration Certification, TrustMark or PAS 2030 schemes, you've come to the right place. Oil Pipeline Detectable Warning Tape. 75mm x 50M. A plastic warning tape with a twin, stainless steel tracer wire system. Two wires are laminated within the tape. The continuous ‘wave’ pattern, allows the tape to stretch by over 25%, thus helping combat underground movement.